• Certified Lab Equipment & Reagents
  • Fast Dispatch on In-Stock Items
  • Expert Scientific Support

Product details

JC-1 Fluorescent Mitochondrial Membrane Depolarization Assay

Catalog number 911

Discontinued

Price for 911

Sign In for Pricing

Size / count 400 Tests

This variant is discontinued and cannot be added to your cart.

About this product

JC-1 accumulates and fluoresces orange in polarized mitochondria. Following membrane depolarization, JC-1 disperses within the cell and fluoresces green. Analyze using a flow cytometer, fluorescence plate reader, or fluorescence microscopy.

Specifications

Catalog number
911
Size / count
400 Tests
Dry ice
No
Hazardous
No
Discontinued
Yes
Specifications
JC-1
Target
Mitochondrial depolarization
Label
ICT
Cell Type
Jurkat, HL-60
Type
Cell Viabiity
Detection Method
Flow Cytometry, Fluorescence Microscope, Fluorescence Plate Reader
Wavelength
488 nm / 590 nm & 527 nm
Assay Protocol
1. Prepare samples and controls, 2. Dilute 10X Apoptosis Wash Buffer 1:10 with diH20., 3. Reconstitute FLICA with 50 μL DMSO., 4. Dilute FLICA 1:5 by adding 200 μL PBS., 5. Add diluted FLICA to each sample at 1:30 (e.g., add 10 μL to 290 μL of cultured cells)., 6. Incubate approximately 1 hour., 7. Remove media and wash cells 3 times: add 1X Apoptosis Wash Buffer and spin cells., 8. If desired, label with additional stains, such as Hoechst, Propidium Iodide, 7-AAD, or an antibody., 9. If desired, fix cells., 10. Analyze with a fluorescence microscope, fluorescence plate reader, or flow cytometer. FAM FLICA excites at 492 nm and emits at 520 nm., , If working with adherent cells, please see the manual for additional protocols.
Sample Type
Cell culture
Components
Kit 911: 400 Tests, MitoPT JC-1 Reagent, 400 Tests, #6260, 10X Assay Buffer (2 x 125 mL), #6259, CCCP, 50 mM, 600 µL, #6258, Kit Manual
Shipping Conditions
Ships overnight (domestic), International Priority Shipping
Storage Temperature
-20°C
Cellular Imaging & Detection
Mitochondrial
Target Description
Mitochondria play a central role in the biochemical processes associated with the life and death stages of eukaryotic cells. Under normal physiological conditions, a membrane-based proton pump generates an electrochemical gradient, enabling the production of ATP to drive cellular energy-dependent processes. The oxidation of glucose and fatty acids by enzymes associated with the mitochondrial respiratory chain establishes a proton and pH gradient across the mitochondrial inner membrane, resulting in a transmembrane electrical potential gradient (∆Ψm) of -80 to -120 mV and a pH gradient of 0.5-1.0 pH units. Depolarization of the inner mitochondrial membrane can lead to an opening of the mitochondrial permeability transition pore (PTP). This results in the leakage of intermembrane proteins, including cytochrome C, that facilitate the induction of apoptosis through apoptosome formation. Caspase activation has been shown to accelerate the process of ∆Ψm loss. Moreover, a feedback mechanism that results in the generation of reactive oxygen species further accelerates the rate of cell death. Because mitochondrial dysfunction has been closely tied to such neurodegenerative diseases as Alzheimer's, Parkinson's, and amyotrophic lateral sclerosis, mitochondria remain an important organelle of study. Loss of mitochondrial ∆Ψm, indicative of apoptosis, can easily be detected using lipophilic, cationic fluorescent redistribution dyes such as ICT’s Fluorescent Mitochondrial Membrane Depolarization Assay reagents: tetramethylrhodamine ethyl ester (TMRE), tetramethylrhodamine methyl ester (TMRM), and 5,5’,6,6’-tetrachloro-1,1’,3,3’-tetraethylbenzimidazolocarbocyanine iodide (JC-1). These dyes have a delocalized positive charge dispersed throughout their molecular structure, and yet their lipophilic solubility enables them to be readily membrane permeant and penetrate living cells. They redistribute across cell membranes according to the Nernst equation in a voltage-dependent manner. Accordingly, they possess a low membrane partition coefficient; meaning a low tendency to non-specifically associate with intracellular organelles and macro- molecules. These excellent potentiometric dyes also exhibit minimal self-quenching, low cytotoxicity, and are reasonably photostable. The Fluorescent Mitochondrial Membrane Depolarization Assay dyes exhibit very low toxicity and display rapid and reversible membrane equilibration properties. ICT’s JC-1 Fluorescent Mitochondrial Membrane Depolarization Assay kits easily distinguish between healthy, non-apoptotic cell populations and those cell populations that are transitioning into an apoptotic state. Inside a healthy, non-apoptotic cell, the lipophilic JC-1 dye, bearing a delocalized positive charge, enters the negatively charged mitochondria where it accumulates. JC-1 no longer accumulates inside the mitochondria, instead becoming more evenly distributed throughout the cytosol. When dispersed in this manner, overall cellular fluorescence levels drop dramatically. Healthy cells fluoresce orange and green, whereas cells with depolarized mitochondria fluoresce green and exhibit lower levels of orange fluorescence. JC-1 Fluorescent Mitochondrial Membrane Depolarization Assay kits can be used in conjunction with other existing research protocols. Grow cells following the usual cell cultivation protocol. If using an apoptosis induction model system, simply induce apoptosis according to the existing procedure, reserving a non-induced population of cells as a control. Once apoptosis has been induced in the cells, or the mitochondrial membrane has been depolarized by another method, such as using CCCP (included in the kit), spike JC-1 dye solution into each sample and control. Incubate the cells for 15-30 minutes at 37°C to allow JC-1 reagent to equilibrate within the polarized mitochondria. If the cells are not undergoing some form of metabolic or apoptotic stress, the mitochondrial ∆Ψm will remain intact, and JC-1 reagent will accumulate within the slightly negative/alkaline environment of the mitochondria and fluoresce brightly upon excitation. If the cells are apoptotic, the mitochondrial ∆Ψm will break down, causing JC-1 reagent to disperse throughout the cell cytosol. This results in a dramatic reduction in the fluorescence of the affected mitochondria, and as a result, overall cellular fluorescence is diminished significantly. Fluorescent Mitochondrial Membrane Depolarization Assays are for research use only. Not for use in diagnostic procedures.

Frequently Asked Questions

What is the catalog number for JC-1 Fluorescent Mitochondrial Membrane Depolarization Assay?

The catalog number for JC-1 Fluorescent Mitochondrial Membrane Depolarization Assay is 911.

Is JC-1 Fluorescent Mitochondrial Membrane Depolarization Assay in stock?

JC-1 Fluorescent Mitochondrial Membrane Depolarization Assay is currently made to order / not held in immediate stock. Contact us for lead time.

What is JC-1 Fluorescent Mitochondrial Membrane Depolarization Assay used for?

JC-1 accumulates and fluoresces orange in polarized mitochondria. Following membrane depolarization, JC-1 disperses within the cell and fluoresces green. Analyze using a flow cytometer, fluorescence plate reader, or fluorescence microscopy.

What is the recommended incubation time for this antibody?

A suggested incubation time is provided in the recommended protocol on the datasheet, but may need adjusting depending on your sample type and detection system.

What should I check when this product first arrives?

Inspect the package immediately for transportation damage, ice loss, leakage, or breakage. Report any issues right away with photos and your order reference; our specialists will determine whether the product is still usable or needs replacing.

Does this cell line or biologic require a Material Transfer Agreement (MTA)?

Some products, including certain cell lines, plasmids, and tissue cultures, are subject to intellectual property terms and may require an MTA before we can ship. We’ll inform you in advance if this product requires one, and additional handling fees may apply.

You Might Also Like
CD44 Standard (156-3C11), CF488A conjugate, 0.1mg/mL
CD44 Standard (156-3C11), CF488A conjugate, 0.1mg/mL
By Afraxis
Sign In for Pricing
Ref: BNC880460-100
CD50 (ICAM-3) (101-1D2), CF488A conjugate, 0.1mg/mL
CD50 (ICAM-3) (101-1D2), CF488A conjugate, 0.1mg/mL
By Afraxis
Sign In for Pricing
Ref: BNC880177-100
CD34 (ICO-115), CF568 conjugate, 0.1mg/mL
CD34 (ICO-115), CF568 conjugate, 0.1mg/mL
By Afraxis
Sign In for Pricing
Ref: BNC680039-100
CD50 (ICAM-3) (186-2G9), CF640R conjugate, 0.1mg/mL
CD50 (ICAM-3) (186-2G9), CF640R conjugate, 0.1mg/mL
By Afraxis
Sign In for Pricing
Ref: BNC400178-500
CD8 (C8/468), CF740 conjugate, 0.1mg/mL
CD8 (C8/468), CF740 conjugate, 0.1mg/mL
By Afraxis
Sign In for Pricing
Ref: BNC740468-100
UACA / Nucling (AE-5), CF405S conjugate, 0.1mg/mL
UACA / Nucling (AE-5), CF405S conjugate, 0.1mg/mL
By Afraxis
Sign In for Pricing
Ref: BNC040956-500
TRP1 (Tyrosinase Related Protein 1) (TYRP1/807), CF594 conjugate, 0.1mg/mL
TRP1 (Tyrosinase Related Protein 1) (TYRP1/807), CF594 conjugate, 0.1mg/mL
By Afraxis
Sign In for Pricing
Ref: BNC940807-100