- Catalog number
- EK2115
- Size / count
- 96 Well With Removable Strips
- Dry ice
- No
- Hazardous
- No
- Discontinued
- No
- Background
- This gene is a member of the leukocyte immunoglobulin-like receptor (LIR) family, which is found in a gene cluster at chromosomal region 19q13.4. The encoded protein belongs to the subfamily B class of LIR receptors which contain two or four extracellular immunoglobulin domains, a transmembrane domain, and two to four cytoplasmic immunoreceptor tyrosine-based inhibitory motifs (ITIMs) . Several other LIR subfamily B receptors are expressed on immune cells where they bind to MHC class I molecules on antigen-presenting cells and inhibit stimulation of an immune response. Multiple transcript variants encoding different isoforms have been found for this gene.
- Reproducibility
- Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 316 297 305 322 310 19.22 5.2% Sample 2 1622 1529 1646 1531 1582 96.50 6.1% Sample 3 4807 4976 4716 4921 4855 398.11 8.2% Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 316 297 305 322 310 19.22 5.2% Sample 1 316 297 305 322 310 19.22 5.2% Sample 2 1622 1529 1646 1531 1582 96.50 6.1% Sample 2 1622 1529 1646 1531 1582 96.50 6.1% Sample 3 4807 4976 4716 4921 4855 398.11 8.2% Sample 3 4807 4976 4716 4921 4855 398.11 8.2%
- Gene Name
- LILRB5
- Gene ID
- 10990
- UniProt
- O75023
- Reactivity
- Human
- Cross Reactivity
- There is no detectable cross-reactivity with other relevant proteins.
- Immunogen
- Expression system for standard: NS0; Immunogen sequence: G24-G458
- Capture Antibody
- A polyclonal antibody from goat
- Detection Antibody
- A biotinylated polyclonal antibody from goat
- Applications
- ELISA
- Standard
- 10 ng/Tube
- Sample Type
- Cell culture supernatants, serum and plasma (heparin, EDTA, citrate) .
- Detection Range
- 156 pg/mL - 10,000 pg/mL
- Precision
- Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 316 1622 4807 329 1719 5032 Standard deviation 18.33 72.99 293.23 25.33 147.83 367.34 CV (%) 5.8% 4.5% 6.1% 7.7% 8.6% 7.3% Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 316 1622 4807 329 1719 5032 Standard deviation 18.33 72.99 293.23 25.33 147.83 367.34 CV (%) 5.8% 4.5% 6.1% 7.7% 8.6% 7.3% Intra-Assay Precision Inter-Assay Precision Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 n 16 16 16 24 24 24 Mean (pg/ml) 316 1622 4807 329 1719 5032 Mean (pg/ml) 316 1622 4807 329 1719 5032 Standard deviation 18.33 72.99 293.23 25.33 147.83 367.34 Standard deviation 18.33 72.99 293.23 25.33 147.83 367.34 CV (%) 5.8% 4.5% 6.1% 7.7% 8.6% 7.3% CV (%) 5.8% 4.5% 6.1% 7.7% 8.6% 7.3%
- Sensitivity
- <15 pg/mL
- Components
- Description|Quantity Pre-coated 96-well strip microplate|1 Standard|2 vials Biotinylated antibody (100x) |100ul Avidin-Biotin-Peroxidase Complex (100x) |100ul Sample Diluent|30ml Antibody Diluent|12ml Avidin-Biotin-Peroxidase Diluent|12ml Color Developing Reagent (TMB) |10ml Stop Solution|10ml Wash Buffer (25x) |20ml Adhesive plate sealers|4
- Storage Conditions
- Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
- Specificity
- Natural and recombinant human LILRB5
- Anticoagulant
- Heparin, EDTA or citrate
- Sample Data
- Concentration (pg/ml) 0 156 312 625 1250 2500 5000 10000 O.D. 0.063 0.157 0.208 0.314 0.582 0.924 1.437 2.013 Concentration (pg/ml) 0 156 312 625 1250 2500 5000 10000 O.D. 0.063 0.157 0.208 0.314 0.582 0.924 1.437 2.013 Concentration (pg/ml) 0 156 312 625 1250 2500 5000 10000 Concentration (pg/ml) 0 156 312 625 1250 2500 5000 10000 O.D. 0.063 0.157 0.208 0.314 0.582 0.924 1.437 2.013 O.D. 0.063 0.157 0.208 0.314 0.582 0.924 1.437 2.013
- Material Required But Not Provided
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional) . Pipettes and pipette tips capable of precisely dispensing 0.5 μl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution.