- Catalog number
- EK2205
- Size / count
- 96 Well With Removable Strips
- Dry ice
- No
- Hazardous
- No
- Discontinued
- No
- Background
- The protein encoded by this gene catalyzes the formation of 5-oxoproline from gamma-glutamyl dipeptides, the penultimate step in glutathione catabolism, and may play a critical role in glutathione homeostasis. The encoded protein may also play a role in cell proliferation, and the expression of this gene is a potential marker for cancer. Pseudogenes of this gene are located on the long arm of chromosome 5 and the short arm of chromosomes 2 and 20. Alternatively spliced transcript variants encoding multiple isoforms have been observed for this gene.
- Reproducibility
- Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 181 179 168 202 183 8.76 4.8% Sample 2 452 469 448 486 464 24.58 5.3% Sample 3 841 869 851 883 861 47.36 5.5% Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 181 179 168 202 183 8.76 4.8% Sample 1 181 179 168 202 183 8.76 4.8% Sample 2 452 469 448 486 464 24.58 5.3% Sample 2 452 469 448 486 464 24.58 5.3% Sample 3 841 869 851 883 861 47.36 5.5% Sample 3 841 869 851 883 861 47.36 5.5%
- Gene Name
- GGCT
- Gene ID
- 79017
- UniProt
- O75223
- Reactivity
- Human
- Cross Reactivity
- There is no detectable cross-reactivity with other relevant proteins.
- Immunogen
- Expression system for standard: E.coli; Immunogen sequence: M1-L188
- Capture Antibody
- A monoclonal antibody from mouse
- Detection Antibody
- A biotinylated polyclonal antibody from goat
- Applications
- ELISA
- Standard
- 10 ng/Tube
- Sample Type
- Cell culture supernatants, serum and plasma (heparin, EDTA)
- Detection Range
- 62.5 pg/mL - 4,000 pg/mL
- Precision
- Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 181 452 841 223 489 892 Standard deviation 9.59 23.05 49.62 10.04 19.07 41.92 CV (%) 5.3% 5.1% 5.9% 4.5% 3.9% 4.7% Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 181 452 841 223 489 892 Standard deviation 9.59 23.05 49.62 10.04 19.07 41.92 CV (%) 5.3% 5.1% 5.9% 4.5% 3.9% 4.7% Intra-Assay Precision Inter-Assay Precision Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 n 16 16 16 24 24 24 Mean (pg/ml) 181 452 841 223 489 892 Mean (pg/ml) 181 452 841 223 489 892 Standard deviation 9.59 23.05 49.62 10.04 19.07 41.92 Standard deviation 9.59 23.05 49.62 10.04 19.07 41.92 CV (%) 5.3% 5.1% 5.9% 4.5% 3.9% 4.7% CV (%) 5.3% 5.1% 5.9% 4.5% 3.9% 4.7%
- Sensitivity
- <10 pg/mL
- Components
- Description|Quantity Pre-coated 96-well strip microplate|1 Standard|2 vials Biotinylated antibody (100x) |100ul Avidin-Biotin-Peroxidase Complex (100x) |100ul Sample Diluent|30ml Antibody Diluent|12ml Avidin-Biotin-Peroxidase Diluent|12ml Color Developing Reagent (TMB) |10ml Stop Solution|10ml Wash Buffer (25x) |20ml Adhesive plate sealers|4
- Storage Conditions
- Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
- Specificity
- Natural and recombinant human GGCT
- Sample Data
- Concentration (pg/ml) 0 62.5 125 250 500 1000 2000 4000 O.D. 0.009 0.072 0.123 0.217 0.423 0.828 1.55 2.223 Concentration (pg/ml) 0 62.5 125 250 500 1000 2000 4000 O.D. 0.009 0.072 0.123 0.217 0.423 0.828 1.55 2.223 Concentration (pg/ml) 0 62.5 125 250 500 1000 2000 4000 Concentration (pg/ml) 0 62.5 125 250 500 1000 2000 4000 O.D. 0.009 0.072 0.123 0.217 0.423 0.828 1.55 2.223 O.D. 0.009 0.072 0.123 0.217 0.423 0.828 1.55 2.223
- Material Required But Not Provided
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional) . Pipettes and pipette tips capable of precisely dispensing 0.5 μl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution.