- Catalog number
- EK2270
- Size / count
- 96 Well With Removable Strips
- Dry ice
- No
- Hazardous
- No
- Discontinued
- No
- Background
- Osteoclasts are multinucleated cells that resorb bone and are essential for bone homeostasis. This gene encodes an osteoclast-associated receptor (OSCAR), which is a member of the leukocyte receptor complex protein family that plays critical roles in the regulation of both innate and adaptive immune responses. The encoded protein may play a role in oxidative stress-mediated atherogenesis as well as monocyte adhesion. Multiple alternatively spliced transcript variants encoding different isoforms have been found for this gene.
- Reproducibility
- Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 233 204 263 232 233 15.52 6.7% Sample 2 463 406 625 332 457 10.09 2.2% Sample 3 4178 2680 3831 3264 3488 223.25 6.4% Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 233 204 263 232 233 15.52 6.7% Sample 1 233 204 263 232 233 15.52 6.7% Sample 2 463 406 625 332 457 10.09 2.2% Sample 2 463 406 625 332 457 10.09 2.2% Sample 3 4178 2680 3831 3264 3488 223.25 6.4% Sample 3 4178 2680 3831 3264 3488 223.25 6.4%
- Gene Name
- OSCAR
- Gene ID
- 126014
- UniProt
- Q8IYS5
- Reactivity
- Human
- Cross Reactivity
- There is no detectable cross-reactivity with other relevant proteins.
- Immunogen
- Expression system for standard: E.coli; Immunogen sequence: M1-F219
- Capture Antibody
- Polyclonal antibody from goat
- Detection Antibody
- Polyclonal antibody from goat
- Applications
- ELISA
- Standard
- 10 ng/Tube
- Sample Type
- Cell culture supernatants, serum and plasma (heparin, EDTA) .
- Detection Range
- 156 pg/mL - 10,000 pg/mL
- Precision
- Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 233 463 4178 165 552 4061 Standard deviation 10.42 33.61 166.57 9.62 37.81 189.24 CV (%) 4.5% 7.3% 2.8% 5.8% 6.9% 4.7% Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 233 463 4178 165 552 4061 Standard deviation 10.42 33.61 166.57 9.62 37.81 189.24 CV (%) 4.5% 7.3% 2.8% 5.8% 6.9% 4.7% Intra-Assay Precision Inter-Assay Precision Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 n 16 16 16 24 24 24 Mean (pg/ml) 233 463 4178 165 552 4061 Mean (pg/ml) 233 463 4178 165 552 4061 Standard deviation 10.42 33.61 166.57 9.62 37.81 189.24 Standard deviation 10.42 33.61 166.57 9.62 37.81 189.24 CV (%) 4.5% 7.3% 2.8% 5.8% 6.9% 4.7% CV (%) 4.5% 7.3% 2.8% 5.8% 6.9% 4.7%
- Sensitivity
- <75 pg/mL
- Components
- Description|Quantity Pre-coated 96-well strip microplate|1 Standard|2 vials Biotinylated antibody (100x) |100ul Avidin-Biotin-Peroxidase Complex (100x) |100ul Sample Diluent|30ml Antibody Diluent|12ml Avidin-Biotin-Peroxidase Diluent|12ml Color Developing Reagent (TMB) |10ml Stop Solution|10ml Wash Buffer (25x) |20ml Adhesive plate sealers|4
- Storage Conditions
- Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
- Specificity
- Natural and recombinant human OSCAR
- Anticoagulant
- Heparin or EDTA
- Sample Data
- Concentration (pg/ml) 0 156 312 625 1250 2500 5000 10000 O.D. 0.062 0.181 0.304 0.47 0.775 1.228 1.704 2.065 Concentration (pg/ml) 0 156 312 625 1250 2500 5000 10000 O.D. 0.062 0.181 0.304 0.47 0.775 1.228 1.704 2.065 Concentration (pg/ml) 0 156 312 625 1250 2500 5000 10000 Concentration (pg/ml) 0 156 312 625 1250 2500 5000 10000 O.D. 0.062 0.181 0.304 0.47 0.775 1.228 1.704 2.065 O.D. 0.062 0.181 0.304 0.47 0.775 1.228 1.704 2.065
- Material Required But Not Provided
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional) . Pipettes and pipette tips capable of precisely dispensing 0.5 μl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution.