- Catalog number
- EK2281
- Size / count
- 96 Well With Removable Strips
- Dry ice
- No
- Hazardous
- No
- Discontinued
- No
- Background
- Osteoclasts are multinucleated cells that resorb bone and are essential for bone homeostasis. This gene encodes an osteoclast-associated receptor (OSCAR), which is a member of the leukocyte receptor complex protein family that plays critical roles in the regulation of both innate and adaptive immune responses. The encoded protein may play a role in oxidative stress-mediated atherogenesis as well as monocyte adhesion. Multiple alternatively spliced transcript variants encoding different isoforms have been found for this gene.
- Reproducibility
- Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 85 104 86 140 104 4.59 4.4% Sample 2 218 289 184 163 214 14.43 6.8% Sample 3 2107 2156 1988 1334 1896 41.53 2.2% Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 85 104 86 140 104 4.59 4.4% Sample 1 85 104 86 140 104 4.59 4.4% Sample 2 218 289 184 163 214 14.43 6.8% Sample 2 218 289 184 163 214 14.43 6.8% Sample 3 2107 2156 1988 1334 1896 41.53 2.2% Sample 3 2107 2156 1988 1334 1896 41.53 2.2%
- Gene Name
- Oscar
- Gene ID
- 232790
- UniProt
- Q8VBT3
- Reactivity
- Mouse
- Cross Reactivity
- There is no detectable cross-reactivity with other relevant proteins.
- Immunogen
- Expression system for standard: NS0; Immunogen sequence: D19-N228
- Capture Antibody
- Polyclonal antibody from goat
- Detection Antibody
- Polyclonal antibody from goat
- Applications
- ELISA
- Standard
- 10 ng/Tube
- Sample Type
- Cell culture supernatants, serum and plasma (heparin, EDTA) .
- Detection Range
- 78 pg/mL - 5,000 pg/mL
- Precision
- Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 85 218 2107 108 167 2056 Standard deviation 2.11 7.56 107.04 4.27 4.63 134.67 CV (%) 2.5% 3.5% 5.1% 4% 2.8% 6.6% Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 85 218 2107 108 167 2056 Standard deviation 2.11 7.56 107.04 4.27 4.63 134.67 CV (%) 2.5% 3.5% 5.1% 4% 2.8% 6.6% Intra-Assay Precision Inter-Assay Precision Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 n 16 16 16 24 24 24 Mean (pg/ml) 85 218 2107 108 167 2056 Mean (pg/ml) 85 218 2107 108 167 2056 Standard deviation 2.11 7.56 107.04 4.27 4.63 134.67 Standard deviation 2.11 7.56 107.04 4.27 4.63 134.67 CV (%) 2.5% 3.5% 5.1% 4% 2.8% 6.6% CV (%) 2.5% 3.5% 5.1% 4% 2.8% 6.6%
- Sensitivity
- <10 pg/mL
- Components
- Description|Quantity Pre-coated 96-well strip microplate|1 Standard|2 vials Biotinylated antibody (100x) |100ul Avidin-Biotin-Peroxidase Complex (100x) |100ul Sample Diluent|30ml Antibody Diluent|12ml Avidin-Biotin-Peroxidase Diluent|12ml Color Developing Reagent (TMB) |10ml Stop Solution|10ml Wash Buffer (25x) |20ml Adhesive plate sealers|4
- Storage Conditions
- Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
- Specificity
- Natural and recombinant human LY96
- Anticoagulant
- Heparin or EDTA
- Sample Data
- Concentration (pg/ml) 0 78 156 312 625 1250 2500 5000 O.D. 0.023 0.072 0.137 0.269 0.584 0.968 1.769 2.851 Concentration (pg/ml) 0 78 156 312 625 1250 2500 5000 O.D. 0.023 0.072 0.137 0.269 0.584 0.968 1.769 2.851 Concentration (pg/ml) 0 78 156 312 625 1250 2500 5000 Concentration (pg/ml) 0 78 156 312 625 1250 2500 5000 O.D. 0.023 0.072 0.137 0.269 0.584 0.968 1.769 2.851 O.D. 0.023 0.072 0.137 0.269 0.584 0.968 1.769 2.851
- Material Required But Not Provided
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional) . Pipettes and pipette tips capable of precisely dispensing 0.5 μl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution.