Product details
Catalog number BNC681237-500
Price for BNC681237-500
Size / count 1x 500 µL
Recognizes a 27 kDa protein, identified as the p27/Kip1, a cell cycle regulatory mitotic inhibitor. Its epitope spans between aa 83-204 of p27. It is highly specific and shows no cross-reaction with other related mitotic inhibitors. p27/Kip1 functions as a negative regulator of G1 progression and has been proposed to function as a possible mediator of TGF-beta-induced G1 arrest. p27/Kip1 is a candidate tumor suppressor gene. This MAb co-precipitates cdk4 in complex p27/Kip1 and is excellent for staining of formalin-fixed tissues. Primary antibodies are available purified, or with a selection of fluorescent CF® Dyes and other labels. CF® Dyes offer exceptional brightness and photostability. Note: Conjugates of blue fluorescent dyes like CF®405S and CF®405M are not recommended for detecting low abundance targets, because blue dyes have lower fluorescence and can give higher non-specific background than other dye colors.
The catalog number for P27 / KIP1 (DCS-72.F6 + KIP1/769 (SX53G8) ), CF568 conjugate, 0.1mg/mL is BNC681237-500.
P27 / KIP1 (DCS-72.F6 + KIP1/769 (SX53G8) ), CF568 conjugate, 0.1mg/mL is available in the following size(s): 1x 500 µL.
P27 / KIP1 (DCS-72.F6 + KIP1/769 (SX53G8) ), CF568 conjugate, 0.1mg/mL is currently made to order / not held in immediate stock. Contact us for lead time.
P27 / KIP1 (DCS-72.F6 + KIP1/769 (SX53G8) ), CF568 conjugate, 0.1mg/mL is manufactured by Biotium.
Estimated delivery time for P27 / KIP1 (DCS-72.F6 + KIP1/769 (SX53G8) ), CF568 conjugate, 0.1mg/mL is approximately 15 business day(s), depending on your location.
The safety data sheet for P27 / KIP1 (DCS-72.F6 + KIP1/769 (SX53G8) ), CF568 conjugate, 0.1mg/mL is available here: https://cdn.gentaur.com/products/37/68dd02b1061270361e109d39/msds/bnc681237-500.pdf.
Recognizes a 27 kDa protein, identified as the p27/Kip1, a cell cycle regulatory mitotic inhibitor. Its epitope spans between aa 83-204 of p27. It is highly specific and shows no cross-reaction with other related mitotic inhibitors. p27/Kip1 functions as a negative regulator of G1 progression and ha
A recommended dilution range for each validated application is provided on the datasheet, but optimal dilution should be titrated for your specific experimental system, sample type, and detection method.
Post-reconstitution storage guidance is listed on the datasheet, typically requiring aliquoting and storage at -20°C or -80°C to preserve activity.
Multiplex compatibility depends on the specific product and detection panel. Contact our technical support team with details of your multiplex system for guidance before ordering.