Product details
Catalog number BNC471222-500
Price for BNC471222-500
Size / count 1x 500 µL
UACA (Uveal Autoantigen with Coiled-coil domains and Ankyrin repeats) is a 1,416 amino acid nuclear membrane protein. It was originally identified as an autoantigen in patients with panuveitis, a characteristic of Vogt-Koyanagi-Harada disease, and in patients with Graves' disease. UACA was also later identified as Nucling, an mRNA differentially expressed in F9 embryonal carcinoma cells during cardiac muscle differentiation. UACA appears to function as a pro-apoptotic protein that recruits the apaf-1-pro-caspase-9 complex for the induction of apoptosis to mediate the cell-death pathway.Primary antibodies are available purified, or with a selection of fluorescent CF® Dyes and other labels. CF® Dyes offer exceptional brightness and photostability. Note: Conjugates of blue fluorescent dyes like CF®405S and CF®405M are not recommended for detecting low abundance targets, because blue dyes have lower fluorescence and can give higher non-specific background than other dye colors.
The catalog number for UACA / Nucling (UACA/1222), CF647 conjugate, 0.1mg/mL is BNC471222-500.
UACA / Nucling (UACA/1222), CF647 conjugate, 0.1mg/mL is available in the following size(s): 1x 500 µL.
UACA / Nucling (UACA/1222), CF647 conjugate, 0.1mg/mL is currently made to order / not held in immediate stock. Contact us for lead time.
UACA / Nucling (UACA/1222), CF647 conjugate, 0.1mg/mL is manufactured by Biotium.
Estimated delivery time for UACA / Nucling (UACA/1222), CF647 conjugate, 0.1mg/mL is approximately 15 business day(s), depending on your location.
The safety data sheet for UACA / Nucling (UACA/1222), CF647 conjugate, 0.1mg/mL is available here: https://cdn.gentaur.com/products/37/68dd02a0061270361e1039b0/msds/bnc471222-500.pdf.
UACA (Uveal Autoantigen with Coiled-coil domains and Ankyrin repeats) is a 1,416 amino acid nuclear membrane protein. It was originally identified as an autoantigen in patients with panuveitis, a characteristic of Vogt-Koyanagi-Harada disease, and in patients with Graves' disease. UACA was also late
Provide the catalogue number, product name, lot number, and your experimental results to our technical support team. They’ll investigate and, if needed, escalate to the manufacturer, provided the product was used before expiry and stored correctly.
Isotype information such as IgG1 or IgG2a is listed in the product specifications on the datasheet, relevant for selecting compatible detection reagents.
We don’t generally offer free samples, but trial discounts in exchange for feedback and validation results are almost always possible. Contact us with your intended application to arrange one.